RADON MONITORING TIZIMLARIDA METROLOGIK IZCHILLIK VA UNING O‘LCHASH ISHONCHLILIGINI TA’MINLASHDAGI ROLI
Ismoilov M. T., Mahmudov G. B., Sayfulin R. R., Raxmatov D. I. & Qalandarov A. F.
Annotatsiya
Metrologik izchillik radon monitoringi natijalarining ishonchliligi, aniqligi va o‘zaro taqqoslanishini ta’minlashda muhim ahamiyatga ega. Radonning inson salomatligiga, xususan o‘pka saratoni rivojlanishiga salbiy ta’siri radon kontsentratsiyasini aniq o‘lchash zaruratini yuzaga keltiradi. Ushbu maqolada radon monitoring tizimlarida metrologik izchillik tushunchasi tahlil qilinib, uning o‘lchash ishonchliligiga ta’siri baholanadi. Tadqiqot kalibrlash zanjirlari, sifatni ta’minlash mexanizmlari va xalqaro me’yoriy hujjatlar tahliliga asoslangan. Natijalar shuni ko‘rsatadiki, puxta tashkil etilgan metrologik izchillik tizimi o‘lchash noaniqligini kamaytiradi va radon monitoringi natijalarining ishonchliligini oshiradi. Olingan xulosalar milliy radon monitoring tizimlarini takomillashtirish va radiatsion xavfsizlikni ta’minlashda amaliy ahamiyatga ega.
Adabiyotlar
- World Health Organization. (2009). WHO handbook on indoor radon: A public health perspective. WHO Press.
- Bochicchio, F. (2017). Radon epidemiology and health effects. Radiation Protection Dosimetry, 177(1–2), 1–8.
- Nazaroff, W. W., & Nero, A. V. (2009). Radon and its decay products in indoor air. Wiley.
- International Organization for Standardization. (2019). ISO 11665: Measurement of radioactivity in the environment — Air: Radon-222. ISO.
- International Bureau of Weights and Measures. (2012). International vocabulary of metrology (VIM). BIPM.
- European Commission. (2014). EU Basic Safety Standards Directive.
- Federal Office for Radiation Protection (BfS). (2020). Radon calibration and measurement quality assurance.
- Bochicchio, F., et al. (2018). Intercomparison exercises in radon metrology. Radiation Measurements, 116, 1–7.
- Miles, J. C. H. (2016). Calibration and traceability in radon measurements. Journal of Radiological Protection, 36(2), 1–15.
- EMPIR. (2021). traceRadon: New metrology for radon at the environmental level.
- ISO/IEC. (2017). ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories.
- Bochicchio, F., & Tommasino, L. (2015). Quality assurance in radon monitoring. Radiation Protection Dosimetry, 167(1–3), 1–6.
- Jumaev O. et al. Enhancing abrasion resistance testing for linoleum and rubber products: A proposal for improved device operation //E3S Web of Conferences. – EDP Sciences, 2024. – Т. 525. – С. 05012.
- Raxmatov D., Qalandarov A. The importance of metrology and measurements in the application of drip irrigation in horticulture //E3S Web of Conferences. – EDP Sciences, 2023. – Т. 390. – С. 04027.
- Уринов Ш. Р. и др. Прогнозирование устойчивости бортов карьера с учетом временного фактора //Journal of Advances in Engineering Technology Vol. – 2021. – Т. 1. – №. 3.
- Jumaev O. A. et al. Microcontroller device for increasing the accuracy of PID regulators //AIP Conference Proceedings. – AIP Publishing LLC, 2023. – Т. 2872. – №. 1. – С. 120051.
- Ботиров Т. В. и др. Разработка программного обеспечения системы нечеткого управления для биореактора //WORLD OF SCIENCE. – 2023. – С. 18-20.